The threshold is expressed as a percentage of the available PoE power. When this threshold is
reached, a trap will be sent if traps are enabled with the
Example
This example shows how to set the power threshold to 90 on module/unit 1:
C3(su)->set inlinepower threshold 90 1

set inlinepower trap

Use this command to enable or disable the sending of an SNMP trap message for a unit or module
whenever the status of its ports changes, or whenever the unit's power usage threshold is crossed.
Syntax
set inlinepower trap {disable | enable} module-number
Parameters
disable | enable
module-number
Defaults
Sending of traps is disabled by default.
Mode
Switch command, read-write.
Usage
The module's or unit's power usage threshold must be set using the set inlinepower threshold
command as described on page 8-2.
Example
This example shows how to enable inline power trap messaging on module 1:
C3(su)->set inlinepower trap enable 1

set inlinepower detectionmode

Use this command to specify the method the switch will use to detect PDs (powered devices)
connected to its ports.
Syntax
set inlinepower detectionmode {auto | ieee)
Disables or enables inline power trap messaging.
Specifies the module or unit on which to disable or enable trap messaging.
set inlinepower trap
command.