Set Spantree Lpwindow; Show Spantree Lpwindow - Enterasys C3G124-24 Configuration Manual

Stackable switches
Hide thumbs Also See for C3G124-24:
Table of Contents

Advertisement

set spantree lpwindow

Defaults
None.
Mode
Switch command, read-write.
Example
This example shows how to reset the Loop Protect event threshold to the default of 3:
C3(rw)->clear spantree lpthreshold
set spantree lpwindow
Use this command to set the Loop Protect event window value in seconds.
Syntax
set spantree lpwindow value
Parameters
value
Defaults
None.
Mode
Switch command, read-write.
Usage
The Loop Protect Window is a timer value, in seconds, that defines a period during which Loop
Protect events are counted. The default value is 180 seconds. If the timer is set to 0, the event
counter is not reset until the Loop Protect event threshold is reached. If the threshold is reached,
that constitutes a loop protection event.
Example
This example shows how to set the Loop Protect event window to 120 seconds:
C3(rw)->set spantree lpwindow 120

show spantree lpwindow

Use this command to display the current Loop Protect event window value.
Syntax
show spantree lpwindow
13-52 Spanning Tree Configuration
Specifies the number of seconds that comprise the period during which
Loop Protect events are counted. The default event window is 180
seconds.