Show Sflow Pollers - Enterasys C3G124-24 Configuration Manual

Stackable switches
Hide thumbs Also See for C3G124-24:
Table of Contents

Advertisement

Usage
A poller instance performs counter sampling on the data source to which it is configured. Refer to
"Sampling
You must first associate a receiver/Collector in the sFlow Receivers Table with the poller instance,
before configuring the polling interval.
When a receiver times out or is cleared from the sFlow Receivers Table, all poller and sampler
instances associated with that receiver are also cleared from the switch's configuration.
Example
The following example configures poller instances on ports ge.1.1 through ge.1.8 and associates
them with receiver 1. Then, a polling interval of 240 seconds is configured.
C3(su)->set sflow port ge.1.1-8 poller 1
C3(su)->set sflow port ge.1.1-8 poller interval 240

show sflow pollers

Use this command to display information about configured poller instances.
Syntax
show sflow pollers
Parameters
None.
Defaults
None.
Mode
Switch command, read-only.
Example
This example displays the output of this command.
C3(su)->show sflow pollers
Poller
Data Source
-----------
ge.1.1
ge.1.2
ge.1.3
ge.1.4
ge.1.5
ge.1.6
ge.1.7
ge.1.8
Mechanisms" on page 37-2 for more information.
Receiver
Poller
Index
Interval
-------
-------
1
240
1
240
1
240
1
240
1
240
1
240
1
240
1
240
show sflow pollers
Enterasys C3 Configuration Guide 37-11