vlan vlan-ID
Defaults
None.
Mode
Switch command, read-write.
Usage
This command allows you to configure the management interface used by the sFlow Agent when
sending sampling datagrams to the sFlow Collector. Any of the interfaces, including VLAN
routing interfaces, can be configured as the management interface.
An interface must have an IP address assigned to it before it can be set by this command.
If no interface is specified, then the Host VLAN will be used as the management interface.
If a non-loopback interface is configured with this command, application packet egress is
restricted to that interface if the server can be reached from that interface. Otherwise, the packets
are transmitted over the first available route. Packets from the application server are received on
the configured interface.
If a loopback interface is configured, and there are multiple paths to the application server, the
outgoing interface (gateway) is determined based on the best route lookup. Packets from the
application server are then received on the sending interface. If route redundancy is required,
therefore, a loopback interface should be configured.
Example
This example configures an IP address on VLAN interface 100 and then sets that interface as the
management interface for the sFlow Agent.
C3(rw)->router(Config-if(Vlan 100))#ip address 192.168.10.1 255.255.255.0
C3(rw)->router(Config-if(Vlan 100))#exit
C3(rw)->router(Config)#exit
C3(rw)->router#exit
C3(rw)->router>exit
C3(rw)->set sflow interface vlan 100
C3(rw)->show sflow interface
vlan 100

show sflow interface

Use this command to display the interface used by the sFlow Agent when sending sampling
datagrams to the sFlow Collector.
Syntax
show sflow interface
Specifies the VLAN interface to be used. The value of vlan-ID can range
from 1 to 4093.
192.168.10.1
show sflow interface
Enterasys C3 Configuration Guide 37-15