User Account and Password Management
The switch is capable of verifying that a specified user is only connected to the product a
configurable number of times (see "set system login simultaneous-logins" on page 5-6). Any
attempt for a specified user to exceed the configured limit results in a trap.
For example, if simultaneous logins is set to 1, a specific user would not be able to Telnet to the
switch, and then simultaneously try to SSH to the switch or access local management via the
console port.
All settings are persistent and show up as part of the running configuration. Passwords are
not displayed in clear text.

Defaults

The default values for user account and password parameters are listed in the following table by
the security mode of the switch. For information about security modes and profiles, see
Setting the Security
Table 5-1 User Account and Password Parameter Defaults by Security Mode
Parameter
Password history
Password change frequency
Minimum number of characters in password
Allow consecutively repeating characters in
password
Aging of system passwords
Password required at time of new user account
creation
Substring matching at password validation
New users required to change password at first
log in
Lockout based on inactivity
Lockout based on failed login attempts
Lockout period duration after unsuccessful logins
Grace period after password expiration
Grace login limit
Warning period
5-4 Setting User Accounts and Passwords
A user account cannot be deleted while it is the emergency access account.
Only one EA user is supported at a time and one shall always exist.
EA status can only be removed by replacing it with another account.
EA user access not made through the console port will be subject to normal password
handling.
The default admin user will be the default EA user.
When the password reset button is enabled, it will restore the default admin account as
the EA user.
Mode.
Normal Mode Default
0 (no history)
0 (no waiting)
8
yes
disabled
no
0 (no checking)
no
0 (no activity checking)
3 failed attempts
15 minutes
0
0
20 days
Chapter
7,
C2 Mode Default
8 previous passwords
1440 minutes (24 hours)
9
2 characters
90 days
yes
0 (no checking)
yes
90 days of inactivity
3 failed attempts
1 minute
30 days
3
20 days