Show Spantree Bridgeprioritymode; Set Spantree Bridgeprioritymode - Enterasys C3G124-24 Configuration Manual

Stackable switches
Hide thumbs Also See for C3G124-24:
Table of Contents

Advertisement

pass-through is enabled, the switch forwards all received BPDUs but does not participate in any
Spanning Tree.
Example
This example shows how to enable BPDU forwarding:
C3(rw)-> set spantree disable
C3(rw)-> set spantree bpdu-forwarding enable

show spantree bridgeprioritymode

Use this command to display the Spanning Tree bridge priority mode setting.
Syntax
show spantree bridgeprioritymode
Parameters
None.
Defaults
None.
Mode
Switch command, read-only.
Example
This example shows how to display the Spanning Tree bridge priority mode setting:
C3(rw)->show spantree bridgeprioritymode
Bridge Priority Mode is set to IEEE802.1t mode.

set spantree bridgeprioritymode

Use this command to set the Spanning Tree bridge priority mode to 802.1D (legacy) or 802.1t.
Syntax
set spantree bridgeprioritymode {8021d | 8021t}
Parameters
8021d
8021t
Defaults
None
Sets the bridge priority mode to use 802.1D (legacy) values, which are 0 -
65535.
Sets the bridge priority mode to use 802.1t values, which are 0 to 61440, in
increments of 4096. Values will automatically be rounded up or down,
depending on the 802.1t value to which the entered value is closest.
This is the default bridge priority mode.
show spantree bridgeprioritymode