set mac agetime

Defaults
None.
Mode
Switch command, read-only.
Example
This example shows how to display the MAC timeout period:
C3(su)->show mac agetime
Aging time: 300 seconds
set mac agetime
Use this command to set the timeout period for aging learned MAC entries.
Syntax
set mac agetime time
Parameters
time
Defaults
None.
Mode
Switch command, read-only.
Example
This example shows how to set the MAC timeout period:
C3(su)->set mac agetime 250

clear mac agetime

Use this command to reset the timeout period for aging learned MAC entries to the default value
of 300 seconds.
Syntax
clear mac agetime
Parameters
None.
Defaults
None.
18-12 Network Management
Specifies the timeout period in seconds for aging learned MAC
addresses. Valid values are 10 to 1,000,000 seconds. Default value is 300
seconds.