The threshold is expressed as a percentage of the available PoE power. When this threshold is 
reached, a trap will be sent if traps are enabled with the set inlinepower trap command.
Example
This example shows how to set the power threshold to 90 on module/unit 1:
C3(su)->set inlinepower threshold 90 1

set inlinepower trap

Use this command to enable or disable the sending of an SNMP trap message for a unit
whenever the status of its ports changes, or whenever the unit's power usage threshold is crossed. 
Syntax
set inlinepower trap {disable | enable} module-number
Parameters
disable | enable
 module‐number
Defaults
Sending of traps is disabled by default.
Mode
Switch command, read‐write.
Usage
The module's or unit's power usage threshold must be set using the set inlinepower threshold 
command as described on page 5‐2.
Example
This example shows how to enable inline power trap messaging on module 1:
C3(su)->set inlinepower trap enable 1

set inlinepower detectionmode

Use this command to specify the method the switch will use to detect PDs (powered devices) 
connected to its ports.
Syntax
set inlinepower detectionmode {auto | ieee)
Disables or enables inline power trap messaging.
Specifies the module or unit on which to disable or enable trap messaging. 
set inlinepower trap
 
or module
SecureStack C3 Configuration Guide 5-3
 