ip irdp maxadvertinterval

ip irdp maxadvertinterval
Use this command to set the maximum interval in seconds between IRDP advertisements. The no
form of this command resets the maximum advertisement interval to the default value of 600
seconds.
Syntax
ip irdp maxadvertinterval interval
no irdp maxadvertinterval
Parameters
interval
Defaults
None.
Mode
Interface configuration: C3
Example
This example shows how to set the maximum IRDP advertisement interval to 1000 seconds on the
VLAN 1 interface:
C3(su)->router(Config)#interface vlan 1
C3(su)->router(Config-if(Vlan 1))#ip irdp maxadvertinterval 1000

ip irdp minadvertinterval

Use this command to set the minimum interval in seconds between IRDP advertisements. The no
form of this command deletes the custom holdtime setting, and resets the minimum
advertisement interval to the default value of three-fourths of the maxadvertinterval value, which
is equal to 450 seconds.
Syntax
ip irdp minadvertinterval interval
no irdp minadvertinterval
Parameters
interval
Defaults
None.
Mode
Interface configuration: C3(su)->router(Config-if(Vlan 1))#
26-12 IPv4 Basic Routing Protocol Configuration
Specifies a maximum advertisement interval in seconds. Valid values are
4 to 1800.
(su)->router(Config-if(Vlan 1))#
Specifies a minimum advertisement interval in seconds. Valid values are 3
to 1800.