Transmit Queue Monitoring Configuration
For information about...
clear txqmonitor
show txqmonitor
show txqmonitor flowcontrol
show txqmonitor port

set txqmonitor

Use this command to enable or disable transmit queue monitoring on the switch. Transmit queue
monitoring is enabled by default.
Syntax
set txqmonitor {enable | disable}
Parameters
enable | disable
Defaults
Monitoring is enabled by default.
Mode
Switch command, read-write.
Example
This example disables transmit queue monitoring on the switch.
C3(su)-> set txqmonitor disable

set txqmonitor downtime

Use this command to configure the time interval, in seconds, that ports disabled by the transmit
queue monitoring feature remain disabled.
Syntax
set txqmonitor downtime seconds
Parameters
seconds
9-2
Enables or disables transmit queue monitoring on the switch.
Monitoring is enabled by default.
Specifies the downtime in seconds. A value of 0 will set the downtime to
forever, meaning that disabled ports will remain disabled until cleared
manually or until their next link state transition.
The default value is 0.
set txqmonitor