Ricoh SAVIN D0AP Service Manual page 530

Table of Contents

Advertisement

SP No.
SP4-008-001
Registration
A: Leading edge registration
B: Side-to-side registration
1.
Put the test chart on the exposure glass. Then make a copy from one of the paper feed
trays.
2.
Check the leading edge and side-to-side registration, and adjust as necessary with the
following SPs.
A: 0 ± 2.0mm
B: 0 ± 2.5mm
SP No.
SP4-010-001
SP4-011-001
SPDF Image Adjustment
Before the scanner adjustment, do the Side-to-Side registration and image position adjustment.
Use A4/LT paper to make a temporary test chart.
Margin Position
1.
Put the temporary test chart on the SPDF. Then make a copy from one of the paper feed
trays.
2.
Check the registrations, and adjust as necessary with following SPs.
Standard: 0 ± 1.5 mm (Main scan), 0 ± 2.0 mm (Sub scan)
SP No.
SP6-006-001
SP6-006-002
SP6-006-010
SP6-006-011
D0AP/D0C4/D0C5/D0C6/M0BQ/M0D1
SP Name
Sub Scan Magnification Adj.
SP Name
Sub Scan Registration Adj.
Main Scan Registration Adj.
SP Name
Side-to-Side Regist:Face
Side-to-Side Regist:Back
L-Edge Regist (1-Pass):Face
L-Edge Regist (1-Pass):Back
6-84
Image Adjustment
Range
± 1.0%
Range
± 1.0 mm
± 2.0 mm
Range
± 3.0 mm
± 2.0 mm
± 5.0 mm
± 5.0 mm