Rev. 04/02/2020
SC No.
Type
•
•
Power cycle the machine to see if the error reoccurs. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power off/on
after each step.
1.
2.
3.
SC No.
Type
SC102-00 D
LED illumination adjustment error
The white level peak reached the prescribed threshold when the scanning
guide plate was scanned after a specified number of adjustments.
•
•
•
•
Power cycle the machine to see if the error reoccurs. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power off/on
after each step.
1.
2.
3.
4.
5.
SC No.
Type
SC111-01 D
LED error (scanning): rear side
The peak white level is less than the prescribed value.
Loose, broken, or defective connector
•
SPDF CIS unit defective
•
•
Harness defective
•
Scanning guide plate is dirty or defective
Engine board defective
•
Power cycle the machine to see if the error reoccurs. If the SC occurs again,
do the following steps. Check if the SC reoccurs by cycling the power off/on
after each step.
1.
Clean and replace the scanning guide plate (rear side).
2.
Reconnect the FFC connectors (SPDF CIS unit to SCB).
3.
Clean and replace the scanning guide plate.
4.
Replace the SPDF CIS unit.
SM
Error Name/Error Condition/Major Cause/Solution
LED driver PCB error
Loose, broken, defective connector or defective harness
Reconnect the FFC connectors (Scanner carriage to SCB).
Replace the scanner carriage.
Replace the FFC (Scanner carriage to SCB).
Error Name/Error Condition/Major Cause/Solution
Loose, broken, or defective connector
Scanner carriage defective
Engine board defective
Harness defective
Reconnect the FFC connectors (scanner carriage to SCB).
Clean and replace the scanning guide plate (exposure glass).
Replace the scanner carriage.
Replace the SCB.
Replace the FFC (scanner carriage to SCB).
Error Name/Error Condition/Major Cause/Solution
6-7
D0AP/D0C4/D0C5/D0C6/M0BQ/M0D1
Service Call