Ricoh SAVIN D0AP Service Manual page 520

Table of Contents

Advertisement

SC No.
Type
SC997-00 B
Application function selection error
The application did not function normally after pressing the application key on
the operation panel.
There is a bug in the software.
SC No.
Type
SC998-00 D
Application start error
D0AP/D0C4/D0C5/D0C6/M0BQ/M0D1
Error Name/Error Condition/Major Cause/Solution
Check if the options required by the application (RAM, DIMM, boards) are
installed properly.
Check whether downloaded applications are correctly configured.
Error Name/Error Condition/Major Cause/Solution
After power ON, no application program was registered to the system
within the specified period of time. (No application started or ended
normally.).
Even though the application started up, it cannot be rendered due to an
unknown fault.
There is a bug in the software.
The options required by the application (RAM, DIMM, board) are not
installed.
Power cycle the machine.
Check the RAM, DIMM, and boards.
Check the application configurations.
Replace the controller board (Printer: Controller board, MF: SCB).