4.7 BIT SWITCHES – 5
Do not adjust a bit switch or use a setting that is described as "Not used", as this may
cause the machine to malfunction or to operate in a manner that is not accepted by
local regulations. Such bits are for use only in other areas, such as Japan.
Default settings for bit switches are not listed in this manual. Refer to the System Parameter List
printed by the machine.

4.7.1 IP FAX SWITCHES

IP Fax Switch 00 (SP No. 1-111-001)
No. Function
0
Not used
1
IP Fax Transport
0: TCP, 1: UDP
2
IP Fax single port
selection
0: OFF, 1: ON
(enable)
3
IP Fax double ports
(single data port)
selection
0: OFF, 1: ON
(enable)
4
IP Fax Gatekeeper
0: OFF, 1: ON
(enable)
5
IP Fax T30 bit signal
reverse
0: LSB first, 1: MSB
first
6
IP Fax max bitrate
setting
0: Not affected, 1:
Affected
7
IP Fax received
telephone number
confirmation
SM
Comments
Do not change this setting.
Selects TCP or UDP protocol for IP-Fax
Selects a single data port.
Selects whether IP-Fax uses a double port.
Enables/disables the gatekeeper for IP-Fax.
Reverses the T30 bit signal.
When "0" is selected, the max bitrate does not affect the value of
the DIS/DCS.
When "1" is selected, the max bitrate affects the value of the
DIS/DCS.
When "0" is selected, fax data is received without checking the
telephone number.
When "1" is selected, fax data is received only when confirming that
89
Bit Switches – 5
D0C5/D0C6/D0C4/D0AP FAX UNIT