■NZ2GFSS2-8D-S1
Unit
Item
Station parameter
Safety setting
I/O LED indication setting at error occurrence
Cyclic data update monitoring time setting
Extension I/O setting
Operation setting of external power supply voltage error detection
Basic module
Wiring selection of input
parameter_main
module
Input response time [main
module]
Double input discrepancy
detection setting
Double input discrepancy
detection type
Double input discrepancy auto recovery setting
Double input discrepancy
detection time
Input dark test execution
setting
Input dark test pulse OFF time setting
Number of pulse output for input dark test
7 VARIOUS SETTINGS
74
7.2 Parameter Settings
Transmission interval monitoring
time
Input response time setting
Output HOLD/CLEAR setting
Wiring selection of input X0 to Wiring
selection of input X7
Input response time X0 to Input
response time X7
Double input discrepancy detection
setting X0/X1 to Double input
discrepancy detection setting X6/X7
Double input discrepancy detection
type X0/X1 to Double input
discrepancy detection type X6/X7
Double input discrepancy detection
time X0/X1 to Double input
discrepancy detection time X6/X7
Input dark test execution setting X0
to Input dark test execution setting
X7
Setting range
4 to 1000ms (default: 35)
0: No indication of error point
(default)
1: Indication of error point
0 to 20 (default: 0)  100ms
0: 0ms
1: 0.2ms
2: 1.0ms
3: 1.5ms
4: 5ms
5: 10ms (default)
6: 20ms
7: 70ms
0: CLEAR (default)
1: HOLD
0: Stop safety communication
(default)
1: Continue safety
communication (Without output
interlock)
2: Continue safety
communication (With output
interlock)
0: Not used (default)
1: Double wiring (NC/NC)
2: Single wiring
0: 1.0ms (default)
1: 1.5ms
2: 5ms
3: 10ms
4: 20ms
5: 50ms
6: 70ms
0: Detect (default)
1: Do not detect
0: Discrepancy detection time
specified (default)
1: Discrepancy detection time not
specified
0: Not used (default)
1: Used
1 to 6000 (default: 1)  10ms
0: Perform (default)
1: Do not perform
0: 400s (default)
1: 1ms
2: 2ms
0: 1 time (default)
1: 2 times
2: 3 times
Reference
Page 37 Safety remote I/O
module safety response time
Page 110 Operation Setting
Function at Detection of
External Power Supply
Voltage Error
Page 85 Safety input wiring
selection function
Page 88 Safety input
response time setting
function
Page 93 Double input
discrepancy detection
function
Page 101 Input dark test
function