Mitsubishi Electric NZ2GFSS2 32D S1 User Manual page 188

Programmable controller cc-link ie field network remote i/o module with safety functions
Table of Contents

Advertisement

■Wiring selection of input
Set the wiring method.
Address
Name
(hexadecimal)
0110H to 0111H
Wiring selection of input
Address: 0110H
b15
b14
b13
Wiring selection of input X3
Address: 0111H
b15
b14
b13
Wiring selection of input X7
• When Xn (n: even number) is set to "1: Double wiring (NC/NC)", only the same setting value as Xn can be
set for Xn+1, the partner of Xn.
• When Xn is set to a value other than "1: Double wiring (NC/NC)", set Xn+1 to a value other than "1: Double
wiring (NC/NC)" as well.
• For unused input terminals, set "0: Not used" in "Wiring selection of input".
■Input response time [main module]
Set the input response time of the input signal.
Address
Name
(hexadecimal)
0120H to 0127H
Input response time [main module]
• Select a longer time than the input dark test pulse OFF time for the parameter. When "1: Do not perform" is
selected in the input dark test execution setting, a shorter time than the input dark test pulse OFF time can
be set for the parameter.
• When the parameter setting of wiring selection of input is set to "0: Not used", this parameter will be ignored.
• When 7 is set, "Parameter data error (input response time): error code 0512H" occurs.
■Double input discrepancy detection setting
Set whether to detect double input discrepancy.
Address
Name
(hexadecimal)
0130H
Double input discrepancy detection setting
b15
b14
b13
0 (fixed)
When "0: Not used" or "2: Single wiring" is selected in the wiring selection of input, this parameter will be
ignored.
APPX
186
Appendix 4 Remote Buffer Memory
b12
b11
b10
b9
Wiring selection of input X2
b12
b11
b10
b9
Wiring selection of input X6
b12
b11
b10
b9
Setting range
0: Not used
1: Double wiring (NC/NC)
2: Single wiring
b8
b7
b6
b5
Wiring selection of input X1
b8
b7
b6
b5
Wiring selection of input X5
Setting range
0: 1.0ms
1: 1.5ms
2: 5ms
3: 10ms
4: 20ms
5: 50ms
6: 70ms
Setting range
0: Detect
1: Do not detect
b8
b7
b6
b5
Default value
0000H
b4
b3
b2
b1
Wiring selection of input X0
b4
b3
b2
b1
Wiring selection of input X4
Default value
0000H
Default value
0000H
b4
b3
b2
b1
X6
X4
X2
X7
X5
X3
b0
b0
b0
X0
X1

Hide quick links: