3.
Drag and drop the icon of the main module from "Module List" to the lower window. At this time, "STA#", "Station Type",
"RX/RY Setting", and "RWw/RWr Setting" are automatically input. Change a value as necessary. To use an extension
module, drag and drop the icon of the extension module from "Module List" to the right side of the main module icon.
4.
Close the "CC IE Field Configuration" window.
[Close with Reflecting the Setting]
5.
After applying the module parameter setting of the master station, write the setting to the programmable controller. For
the module parameter setting of the master station, refer to the following.
 MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
7 VARIOUS SETTINGS
7.1 Network Configuration Settings
7
71