Function List

This section describes the function list, operation modes, and state transition.
Function list
: Available, : Not available
Item
Safety input wiring
selection function
Safety input response
time setting function
Safety output wiring
selection function
Number of safety
output ON times
integration function
Double input
discrepancy detection
function
Input dark test function
Internal input dark test
function
Output dark test
function
Output read-back
function
Protection function
User authentication
function
Operation setting
function at detection of
external power supply
voltage error
Functions available
when extension
modules are
connected
*1 The functions are available when the safety extension module (NZ2EXSS2-8TE) is connected.
*2 The functions are available when the standard extension module is connected.
3 SPECIFICATIONS
40
3.3 Function List
Description
Selects double wiring or single wiring of
the input wiring.
Reduces incorrect inputs caused by
noise of input signals.
Set the time taken from when an
external input turns on/off until when
the input signal is detected in the
module.
Selects double wiring or single wiring of
the output wiring.
Counts the total number of ON times of
each output point.
Discriminates failures by monitoring the
discrepancy state of doubled safety
remote inputs (SA\X).
Outputs test pulses to turn off the
external input signals (X0 to X1F) that
are on and diagnoses contacts
including external devices for failure.
Outputs test pulses to the input circuit
of the safety remote I/O module to
detect a circuit-fixing failure. The test
pulses turn off the external input signals
(X0 to X1F) that are on to detect the
failure.
Outputs test pulses to turn off the
external output signals (Y0 to Y7) that
are on and diagnoses the internal
circuit for failure.
Reads back output results and
diagnoses whether the external output
signals (Y0 to Y7) are correctly output.
Prevents effects due to overvoltage and
overcurrent from spreading to other
modules of the safety system.
Limits the users who can access the
CPU module or safety remote I/O
module.
Users can select whether to continue
safety communication or stop it when
an external power supply voltage error
occurs.
The functions of the safety extension
module or the standard extension
module are available when the
extension module is connected.
Availability
NZ2GFSS2-
NZ2GFSS2-
32D-S1
8D-S1
*1
*2
NZ2GFSS2-
NZ2GFSS2-
8TE-S1
16DTE-S1
*2
*2
Reference
Page 85 Safety input
wiring selection
function
Page 88 Safety input
response time
setting function
Page 89 Safety
output wiring
selection function
Page 92 Number of
safety output ON
times integration
function
Page 93 Double
input discrepancy
detection function
Page 101 Input dark
test function
Page 104 Internal
input dark test
function
Page 105 Output
dark test function
Page 107 Output
read-back function
Page 108 Protection
Functions
Page 109 User
Authentication
Function
Page 110 Operation
Setting Function at
Detection of External
Power Supply
Voltage Error
Page 117 Functions
Available When
Extension Modules
Are Connected