Wiring Of Ethernet Cable - Mitsubishi Electric NZ2GFSS2 32D S1 User Manual

Programmable controller cc-link ie field network remote i/o module with safety functions
Table of Contents

Advertisement

Wiring of Ethernet cable

Connecting the Ethernet cable
■Connecting
*1 The time taken for the LINK LED to turn on after connection of the cable may vary. The LINK LED normally turns on in a few second.
However, if link-up processing is repeated due to a condition of a device on the line, the longer time may be required. If the LINK LED
does not turn on, refer to the following and take a corrective action.
Page 125 When the LINK LED turns off
6 INSTALLATION AND WIRING
60
6.4 Wiring
1.
Power off the module power supply of the safety remote
I/O module and the power supply of the external device.
2.
Push the Ethernet cable connector into the safety
remote I/O module until it clicks. Pay attention to the
connector's direction.
3.
Power on the module power supply.
4.
Power on the power supply of the external device.
5.
Check if the LINK LED on the port into which the
Ethernet cable is connected is on.
*1