Measures To Comply With The Machinery Directive - Mitsubishi Electric NZ2GFSS2 32D S1 User Manual

Programmable controller cc-link ie field network remote i/o module with safety functions
Table of Contents

Advertisement

Measures to comply with the Machinery Directive

The Machinery Directive (2006/42/EC) requires that machinery satisfy the three pillars of safety: mechanical safety, electrical
safety, and worker safety.
This product is suitable for establishing safety functions for general industrial machinery and complies with the Machinery
Directive (2006/42/EC). Before using this product, please read this manual, the relevant manuals, and the safety standards
carefully and pay full attention to safety to handle the product correctly.
The descriptions are based on the requirements of the Machinery Directive and the harmonized standards. However, they do
not guarantee that the entire machinery constructed according to the descriptions complies with the Machinery Directive. The
manufacturer of the machinery must determine the testing method for compliance and declare conformity to the Machinery
Directive.
Standard: EN61000-6-7: 2015
Test item
EN61000-4-2
EN61000-6-7
Electrostatic discharge immunity
EN61000-4-3
EN61000-6-7
Radiated, radio-frequency, electromagnetic
*1
field immunity
EN61000-4-4
Fast transient burst immunity
EN61000-4-5
EN61000-6-7
*1
Surge immunity
EN61000-4-6
EN61000-6-7
*1
Conducted RF immunity
EN61000-4-11
Voltage dips and interruption immunity
EN61000-4-6-16
EN61000-6-7
Conducted common-mode voltage immunity
*1 The module is an open-type device (a device designed to be housed in other equipment) and must be installed inside a conductive
control panel. The tests were conducted with the module installed in a control panel.
APPX
202
Appendix 5 EMC, Low Voltage, and Machinery Directives
Test description
Immunity test in which static electricity is applied to
the cabinet of the equipment
*1
Immunity test in which electric fields are irradiated
to the product
Immunity test in which burst noise is applied to the
*1
power supply line and signal line
Immunity test in which lightning surge is applied to
the power supply line and signal line
Immunity test in which high frequency noise is
applied to the power supply line and signal line
Immunity test in which power supply voltage is
*1
momentarily interrupted
Immunity test in which common-mode noise is
applied to the power lines and signal lines
*1
Value specified in standard
8kV Contact discharge
80% AM modulation @1kHz
• 80 to 1000MHz: 20V/m
• 1.4 to 2.0GHz: 10V/m
• 2.0 to 6.0GHz: 3V/m
• 84.000, 137 to 174, 219.500, 380 to 400, 420 to 470,
698 to 960MHz: 20V/m
• 1.24 to 1.30, 1.428 to 2.0GHz: 10V/m
• 2.0 to 2.7, 3.3 to 3.6, 5.15 to 5.925GHz: 3Vm
• AC main power line: 4kV
• DC main power line: 2kV
• I/O power, DC I/O and communication lines: 2kV
• AC power line: 4kV CM, 2kV DM
• DC I/O Power, DC I/O, communication lines: 2kV CM
80% AM modulation @1kHz
• 0.15 to 80MHz: 20V
• 3.39, 6.780, 13.560, 27.120, 40.680MHz: 20V
• 0%, 1 period, starting at zero crossing
• 0%, 250/300 periods (50/60Hz)
• 40%, 10/12 periods (50/60Hz)
• 70%, 25/30 periods (50/60Hz)
• 1.5 to 15kHz: 1 to 10V
• 15 to 150kHz: 10V
• 16.7, 50, 60, 150, 180Hz: 10V (continuously)
• 16.7, 50, 60Hz: 100V for short period of time (1s)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents