■Module control data area
Address
Name
(hexadecimal)
1000H
Error history clear command
1001H
Error history clear completed
1002H
Parameter area initialization command
1003H
Parameter area initialization completed
1004H
Use prohibited
1005H
Safety module enabled flag
1006H to 10FFH
Use prohibited
*3
1100H
Number of ON times integration value clear command Y0 to YF
*3
1101H
Number of ON times integration value clear completed Y0 to YF
1102H to 11FFH
Use prohibited
1200H to 12FFH
For extension module
*1 This is the value for when the module power supply is turned off and on or at the remote reset.
*2 This column indicates whether reading or writing values using programs is possible.
R: Readable
W: Writable
*3 For the NZ2GFSS2-8D-S1, this address cannot be used.
For the monitoring area of the standard extension module, refer to the following.
 CC-Link IE Field Network Remote I/O Module User's Manual
*1
Default value
Read/Write
0000H
R/W
0000H
R
0000H
R/W
0000H
R
0000H
R
0000H
R/W
0000H
R
APPX
Appendix 4 Remote Buffer Memory