NZ2GFSS2-16DTE-S1 type main I/O combined module
Item
CC-Link IE station type
Number of input points
*2
Rated input voltage
Rated input current
Isolation method
Max. number of simultaneous input points
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Input circuit response time
Safety remote station refresh response processing time
Input response time of safety remote station
External power supply for I/O
*2
part
Power supply current for input device (COM+)
Input type
Withstand voltage
Isolation resistance
Noise immunity
Protection degree
Wiring method for common
Number of output points
Rated load voltage
Maximum load current
Isolation method
Max. inrush current
*5
Leakage current at OFF
Maximum voltage drop at ON
Output circuit response time
Output response time of safety remote station
Surge suppressor
Output type
Wiring method for common
Protection function
External interface
Applicable DIN rail
Applicable wire size
Applicable solderless
terminal
3 SPECIFICATIONS
30
3.2 Performance Specifications
OFF  ON
ON  OFF
Voltage
Current
Protection function
OFF  ON
ON  OFF
Communication part
Module power supply part
I/O part, external power supply
part
Terminal block for module
power supply and FG
I/O terminal block
Terminal block for module
*1
power supply and FG
I/O terminal block
NZ2GFSS2-16DTE-S1
Remote device station
Single wiring: 8 points, double wiring: 4 points
24VDC (ripple ratio: 5% or less) (allowable voltage range: 20.4 to 28.8VDC)
7.0mA TYP. (24VDC)
Photocoupler isolation
100%
12VDC or higher/3mA or higher
5VDC or lower/1.3mA or lower
Approx. 2.6k
0.4ms or less (24VDC)
0.4ms or less (24VDC)
2.0ms
Input circuit response time + Input response time (1.0ms, 1.5ms, 5ms, 10ms, 20ms, 50ms,
70ms)
24VDC (ripple ratio: 5% or less) (allowable voltage range: 20.4 to 28.8VDC)
150mA
External power supply overvoltage protection function, external power supply overcurrent
protection function
0.4A/1 terminal
Negative common
500VAC for 1 minute between all DC external terminals and the ground
10M or higher between all DC external terminals and ground (500VDC isolation resistance
tester)
Noise voltage 500Vp-p, noise width 1s, noise frequency 25 to 60Hz (DC type noise
simulator condition)
IP2X
Input 8 points/common (spring clamp terminal block)
Single wiring: 8 points, double wiring: 4 points
24VDC (ripple ratio: 5% or less) (allowable voltage range: 20.4 to 28.8VDC)
0.5A/point
Photocoupler isolation
1.0A, 10ms or less
0.1mA or lower
0.5VDC (TYP.) 0.5A, 0.8VDC (MAX.) 0.5A
0.4ms or less (24VDC)
0.4ms or less (24VDC)
Output circuit response time
Zener diode
Source + Source type
Output 8 points/common (spring clamp terminal block)
Output overload protection function
RJ45 connector
Terminal block for module power supply and FG (2-piece spring clamp terminal block)
40 points, 2-piece spring clamp terminal block (push-in)
TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715)
Core: 0.3 to 1.5 (22 to 16 AWG)
Core: 0.3 to 1.5 (22 to 16 AWG)
Page 59 List of bar solderless terminals
Page 65 List of bar solderless terminals