Mitsubishi Electric NZ2GFSS2 32D S1 User Manual page 120

Programmable controller cc-link ie field network remote i/o module with safety functions
Table of Contents

Advertisement

Functions that can be used when a standard extension module is connected
The following lists the functions that can be used when a standard extension module is connected.
Item
Input function
Output function
Input OFF delay function
Input response time setting function
Output HOLD/CLEAR setting function
Cyclic data update watch function
Number of ON times integration function
For details on the functions that can be used when a standard extension module is connected, refer to the following manual.
 CC-Link IE Field Network Remote I/O Module User's Manual
• Connect the standard extension module to the main module (NZ2GFSS2-8D-S1, NZ2GFSS2-8TE-S1, or
NZ2GFSS2-16DTE-S1).
• Up to one extension module can be connected. When two or more extension modules are connected,
operations for this module cannot be guaranteed.
• Before connecting a standard extension module or replacing an existing standard extension module with a
new one, turn off the module power supply. If a standard extension module is connected or removed while
the module power supply is on, an error occurs in the safety remote I/O module. For the error state, refer to
the list of error codes. ( Page 137 List of Error Codes)
• When a standard extension module is replaced with a new one, write the parameters to the module again
from the engineering tool.
• If the CPU module of the master station is other than RnSFCPU, operations for the standard extension
module cannot be guaranteed.
8 FUNCTIONS
118
8.8 Functions Available When Extension Modules Are Connected
Description
Acquires the ON/OFF status of the inputs.
Controls the ON/OFF status of the outputs.
Turns off an X signal after a predetermined time has passed from when an actual input becomes off from on.
Prevents an incorrect input due to noise by setting the response time until the module recognizes an actual input
as the X signal.
Sets whether to hold or clear the last output value when the safety remote I/O module is disconnected from data
link, or the CPU module operating status is STOP.
Monitors the update intervals of the cyclic data. The last output value is held or cleared when the cyclic
transmission stop status continues longer than the set monitoring time.
Counts the total number of ON times of each output point. The integration value remains even though the module
is powered off.