Appendix 2
Remote control/monitor signals are used for controlling and monitoring the functions other than the safety functions. Do not
use these signals in a program that operates the safety functions. If any of the signals is used, the correct operation of the
module cannot be guaranteed. The following table shows the list of the remote control/monitor signals for the master station.
Item
Remote control/monitor input signal (RX)
Remote control/monitor output signal (RY)
• The external I/O signals are communicated to the master station using the safety remote I/O signals (SA\X
and SA\Y).
• When "Link Stop" is performed using the CC-Link IE Field Network diagnostics or the cyclic transmission is
stopped from the link special relay (SB) or link special register (SW), the input status of the remote control/
monitor input signal (RX) is retained. Thus, the status may be different from the actual status of the module.

List of remote control/monitor signals

The following table lists the assignment of the remote control/monitor input signals.
Do not use any "Use prohibited" remote control/monitor signals. If any of the signals are used, the correct
operation of the module cannot be guaranteed.
NZ2GFSS2-32D-S1
■Remote control/monitor input signal (RX)
Signal direction: Safety remote I/O module  Master station
Device No.
RX0 to RX6
RX7
RX8, RX9
RXA
RXB
RXC to RXF
RX10 to RX1F
RX20 to RX2F
RX30
RX31
RX32
RX33
RX34
RX35
RX36
RX37
RX38
RX39
RX3A
RX3B
RX3C
RX3D
RX3E
RX3F
APPX
170

Appendix 2 Remote Control/Monitor Signals

Remote Control/Monitor Signals
Description
Control/monitor signals from the safety remote I/O module to the master station
There are no control/monitor signals from the master station to the safety remote I/O module. Using any of RY
signals is not allowed.
Name
Use prohibited
Warning status flag
Use prohibited
Error status flag
Remote READY
Use prohibited
Error code
Warning code
External input monitor X0
External input monitor X1
External input monitor X2
External input monitor X3
External input monitor X4
External input monitor X5
External input monitor X6
External input monitor X7
External input monitor X8
External input monitor X9
External input monitor XA
External input monitor XB
External input monitor XC
External input monitor XD
External input monitor XE
External input monitor XF