Mitsubishi Electric NZ2GFSS2 32D S1 User Manual page 154

Programmable controller cc-link ie field network remote i/o module with safety functions
Table of Contents

Advertisement

■I/O data error (error code: 010BH)
The cause of an I/O data error is stored in Error code details 1. This error occurs only for the NZ2GFSS2-8D-S1 and the
NZ2GFSS2-16DTE-S1.
• Error code details 1
b15
b14
b13
0 (fixed)
(1) Cause of an I/O data error
01: All input points error
10 or 11: Error detected by internal input dark test
Error detection point information is stored in Error code details 2.
• Error code details 2
Values to be stored in Error code details 2 depend on a value stored in Error code details 1.
All points become 0 in Error code details 2 when 01 is stored in Error code details 1.
The diagnostic result of an internal input dark test (normal or error) is stored in Error code details 2 when 10 or 11 is stored in
Error code details 1.
b15
b14
b13
0 (fixed)
0: Normal
1: Error
An action to be taken when an I/O data error has occurred depends on the error cause stored in Error code
details 1. For details, refer to the following.
• All input points error: If an error occurs for all the input points due to the input dark test error (error code:
0205H) or the double input discrepancy detection error (error code: 0204H) and the input function cannot be
performed anymore, a moderate error state of I/O data error (error code: 010BH) is applied. In such a case,
take actions to restore from the previous error state (0205H or 0204H: minor error).
• Error detected by internal input dark test: Correct the wiring on the error detection points indicated in Error
code details 2.
■Remote buffer memory access error (error code: 0202H)
The start address of a remote buffer memory area that was accessed using the REMFR/REMTO instruction is stored in Error
code details 1. For details on the remote buffer memory addresses, refer to the following.
Page 184 Details of remote buffer memory areas
■Double input discrepancy detection error (error code: 0204H)
Occurrence of a double input discrepancy error is stored in Error code details 1. The input signal status after the input
response time has passed is stored in Error code details 3. This error occurs only for the NZ2GFSS2-8D-S1 and the
NZ2GFSS2-16DTE-S1.
• Error code details 1
b15
b14
b13
0 (fixed)
0: Match
1: Mismatch
• Error code details 3
b15
b14
b13
0 (fixed)
0: OFF
1: ON
10 TROUBLESHOOTING
152
10.7 List of Error Codes
b12
b11
b10
b9
b12
b11
b10
b9
b12
b11
b10
b9
b12
b11
b10
b9
b8
b7
b6
b5
b8
b7
b6
b5
X7
X6
X5
b8
b7
b6
b5
b8
b7
b6
b5
X7
X6
X5
b4
b3
b2
b1
(1)
b4
b3
b2
b1
X4
X3
X2
X1
b4
b3
b2
b1
X6
X4
X2
X7
X5
X3
b4
b3
b2
b1
X4
X3
X2
X1
b0
b0
X0
b0
X0
X1
b0
X0

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents