Nortel 2000 Software Reference Manual page 216

Nortel remote annex 2000 server: reference guide
Hide thumbs Also See for 2000:
Table of Contents

Advertisement

Chapter 3
Using the CLI Commands
Remote Annex Administrator's Guide for UNIX
Book C-198
Table C-65. Setting Parameters Using stty (continued)
Parameter
Description
echo
Controls the echoing of characters as they are typed.
–echo
Setting –echo turns off echoing. The default is echo.
flush character
Sets the flush character. When pressed, this character
flushes your output buffer. The default is
forw string
Defines a control character sequence as a forward switch
character or string. Entering this character or string
reopens the next available higher numbered session,
already established at your port. Make sure the selected
control character sequence is not one that is used with
any host applications. To clear an existing switch, enter
a null string ("").
On virtual ports, the switch is limited to one character;
on non-virtual ports, the switch string can range from
1–16 characters.
iflow argument
Specifies the method the Remote Annex uses to stop
input from the terminal if the Remote Annex's input
buffer is about to overflow. The default is bell. Possible
values are:
none
Specifies no flow control; characters are lost if the
buffers overflow.
eia
Selects hardware flow control and works only if the
control_lines parameter is enabled for hardware flow
control and the terminal is wired appropriately.
xonoff
Specifies XON/XOFF flow control. The Remote Annex
sends XOFF when its buffers are nearly full and sends
XON when the buffer level reaches a safe level. This is
known as in-band flow control.
bell
The Remote Annex rings the terminal bell when its input
buffer is full.
(continued on next page)
Book C
.
CTRL-O

Advertisement

Table of Contents
loading

This manual is also suitable for:

4000539061005391

Table of Contents