Nortel DMS 100 Series Maintenance Manual page 50

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

2-34 Maintenance overview
Note: The BSY, RTS, HOLD, and NEXT commands function as hidden
commands from the subtending LTP levels. These commands operate by
the same method as in the root LTP level. The ALMSTAT command does
not provide specified information about a RSC-M line or on the posted link.
Figure 2-8 RSC-M line test configuration near end measurements
Jack
Test
MTM
Equip.
.
297-8223-550 Standard 04.02 November 2000
LTA—used only with the release (RLS) parameter to release monitor
connections to CPB lines
Note: If the monitored line is MB, you can use the LTA, RLS, or RTS
commands to release connections. If the line is CPB, you must use the
LTA RLS command.
RLSCON—releases test equipment connected to a line
RING—sends the correct signal to the AMC subscriber line that has a
monitor connection. This signal causes ringing. Operating company
personnel monitor a MB line. The signal allows operating company
personnel to alert the tester in the field to go off-hook. This action allows
you to monitor line quality.
MAPCI
LTPMAN
DMS
PCM–30 Access
RSCM
Network
Subscriber
Line
MUX
Tone Equip.
or Silent
Termination