11-10 RSC-M recovery procedures
Recovering an out-of-service RSC-M/RCO2
11
12
13
14
15
16
297-8223-550 Standard 04.02 November 2000
If one
or more RCO2 cannot be loaded
or RTS
To post the SysB RCO2, type
>POST RCO2 rco2_no
and press the Enter key.
where
rco2_no
is the number of a RCO2 recorded in step 9
To busy the SysB RCO2, type
>BSY PM
and press the Enter key.
To RTS the SysB RCO2, type
>RTS PM
and press the Enter key.
Note: If the system responds with instructions to RTS one unit after an
RTS PM fails, ignore this message. Follow the instructions in the following
table.
If the RTS
passes on both units
fails on one or both units
To check for fault indicators, type
>QUERYPM
FLT
and press the Enter key.
Determine if one or both units require recovery.
If recovery
is required on both units
is required on one unit
Identify the error message reported in step 14.
If the error reason
is activity dropped
is CC audit
(continued)
Do
step 34
Do
step 33
step 14
Do
step 16
step 34
Do
step 17
step 17