Recovering an out-of-service RSC-M/RCO2
To recover an out of service RSC-M/RCO2
At the MAP display
1
When the system detects a fault, the system can trigger an audible alarm. To
access the peripheral module (PM) level of the MAP display and silence the
alarm, type
>MAPCI;MTC;PM;SIL
and press the Enter key.
2
To display the SysB RCO2, type
>DISP STATE SYSB RCO2
and press the Enter key.
Example of a MAP response:
SysB RCO2: 0
If
one RCO2 is SysB
more than one RCO2 is SysB
3
To access the set of SysB RCO2s, type
>POST RCO2 SYSB
and press the Enter key.
Example of a MAP response:
RCO2
RCO2 1 SysB
Unit0:
Unit1:
4
To recover the SysB RCO2s with the PM recovery tool, type
>RECOVER ALL
and press the Enter key.
Example of a MAP response:
This operation will be executed on n RCO2s.
Please Confirm ("YES" or "NO"):
Note: In the MAP response, n is the number of all RCO2s in the posted
set.
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
SysB
ManB
PM
3
0
RCO2
2
0
Links_OOS:
Act
SysB
Inact SysB
RSC-M recovery procedures
Do
step 5
step 3
Offl
CBsy
ISTb
1
3
2
0
3
0
CSide 0, PSide 0
11-7
(continued)
InSv
13
7