To replace an NTMX79 in an RSC-M
At the MAP display
1
Proceed only if one of the following conditions applies. The maintenance
support group or a step in a maintenance procedure directs you to this card
replacement procedure. Use the procedure to verify or accept cards.
2
Obtain an NTMX79 replacement circuit card. Verify the replacement circuit
card has the same product engineering code (PEC) and suffix as the old
circuit card.
At the MAP terminal
3
Make sure the system displays the peripheral module (PM) level of the MAP
display. To post the RSC-M/RCO2, type
>MAPCI;MTC;PM;POST RCO2 rco2_no
and press the Enter key.
where
Example of a MAP response:
RCO2
0 Quit
2 Post_
3 ListSet
4
5 TRNSL
6 TST
7 BSY
8 RTS
9 OffL
10 LoadPM_
11 Disp_
12 Next_
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
WARNING
Loss of service
To replace a card in the RSC-M, make sure the unit in which
you replace the card is inactive and the mate unit is active.
rco2_no
is the number of the RCO2 with the defective card
SysB
PM
0
RCO2
0
RCO2
0 ISTb
Unit0:
Inact ISTb
Unit1:
Act InSv
RSC-M card replacement procedures
in an RSC-M
ManB
OffL
CBsy
0
2
0
0
0
Links_OOS:
CSide
1, PSide
6-73
NTMX79
(continued)
ISTb
InSv
2
25
0
1
1
1