Nortel DMS 100 Series Maintenance Manual page 215

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

If PMRESET
passes
fails
15
Use the following information to determine the next step in this procedure.
If you enter this procedure from
alarm clearing procedures
other
16
To return the inactive unit to service, type:
>RTS
and press the Enter key.
If the RTS command
passes
fails
17
Remove the sign from the active unit.
18
Go to the common returning a card procedure in this document.
Go to step 22.
19
Return to Alarm Clearing Procedures or other procedure that direct you to
this procedure. Continue as directed.
20
For additional help, contact the next level of maintenance.
21
For additional help with SWACT, contact the next level of maintenance.
Note: The system can recommend that you use the SWACT command
with the FORCE option. Consult office personnel to determine if you must
use the FORCE option.
22
The procedure is complete.
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
unit_no
is the number of the RCO2 unit busied in step 10
INACTIVE
RSC-M card replacement procedures
in an RSC-M
Do
step 15
step 20
Do
step 19
step 16
Do
step 17
step 20
6-63
NTMX76
(end)