5-40 RSC-M alarm clearing procedures
PM RSC-M/RCO2
minor
(continued)
15
16
17
18
19
297-8223-550 Standard 04.02 November 2000
for the ManB link in the example is 2.
If TST
passes and alarm clears
fails
To post the host PM, type
>PM;POST host_pm host_pm_no
and press the Enter key.
where
host_pm
is the PLGC in step 8
host_pm_no
is the number of the PLGC
Use the information in step 7 to determine which RCO2 unit associates with
the SysB link. The unit must be inactive to continue.
If RCO2 unit
is inactive
is active
To RTS the link, type
>RTS LINK link_no
and press the Enter key.
where
link_no
is the number of the link in step 9
Note: Each link in step 9 must be RTS.
To post the RCO2, type
>POST RCO2 rco2_no
and press the Enter key.
where
rco2_no
is the number of the RCO2 in step 2
Note: This RCO2 must be SysB.
To RTS the inactive unit, type
>RTS UNIT unit_no
and press the Enter key.
Do
step 15
step 24
Do
step 21
step 17