Pm Rsc-M/Rco2 Critical - Nortel DMS 100 Series Maintenance Manual

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

5-10 RSC-M alarm clearing procedures
PM RSC-M/RCO2
critical
Alarm display
CM
.
Indication
An nRCO2 *C* under the PM subsystem header at the MTC level of the MAP
display indicates an RSC-M critical alarm.
Note: This section refers to RSC-M/RCO2 as RCO2. When software
generates messages to the MAP terminal, the software does not differentiate
between the two types of RCO2.
Meaning
Both RCO2 units are system-busy (SysB) or C-side busy (CBsy).
Result
Call processing ceases. The RCO2 can be in emergency stand-alone (ESA).
Common procedures
There are no common procedures.
Action
This procedure contains a flowchart and a list of steps. Use the flowchart to
review the procedure. Follow the steps to perform the procedure.
297-8223-550 Standard 04.02 November 2000