Nortel DMS 100 Series Maintenance Manual page 338

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

11-12 RSC-M recovery procedures
Recovering an out-of-service RSC-M/RCO2
19
20
21
22
297-8223-550 Standard 04.02 November 2000
To load unit again, type
>LOADPM UNIT unit_no CC FORCE
and press the Enter key.
where
unit_no
is the number of the unit that did not RTS in step 18
If the LOADPM
passes
fails
Identify the test failure message.
If the display message
is NO REPLY FROM PM
is FAIL
MESSAGE
CEIVED FROM PM
is a card list
indicates a load failure
Determine if the NO REPLY FROM PM message occurred.
If the message
occurred before
did not occur before
To reset the unit, type
>PMRESET UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the unit tested in step 17
Note: During reset, the MAP terminal must indicate the reset events in
sequence. These events appear as displayed in the following MAP
response.
Example of a MAP response:
(continued)
Do
step 18
step 35
Do
step 21
step 35
RE-
step 25
step 27
Do
step 35
step 22