11-14 RSC-M recovery procedures
Recovering an out-of-service RSC-M/RCO2
28
29
30
LINK0 ENET 0 0 30 00
LINK1 ENET 1 0 30 00
LINK2 ENET 0 0 30 00
LINK3 ENET 1 0 30 00
31
32
33
297-8223-550 Standard 04.02 November 2000
unit_no
is the number of the unit to be loaded
If the LOADPM
passes
fails
Identify the failed load in step 27.
If message displayed
is NO WAI AFTER RESET
is FAIL ROM DIAG
is GET ON FILE FAILED
a message does not appear
The message GET ON FILE FAILED indicates a problem with the storage
device. Go to step 35.
To display the status of C-side links, type
>TRNSL C
and press the Enter key.
Example of a MAP response:
0;Cap:MS;Status:OK
0;Cap:MS;Status:SBsy;MsgCond:CLS,Restricted
1;Cap:MS;Status:OK
1;Cap:MS;Status:OK
Note the numbers and conditions of the links.
If the status of the MS links
is CLS
is not OK
is OK
Probable cause is a problem with the network interface card or the ENET port
interface card. Contact the next level of support.
Recover the next RCO2 unit or next RCO2 PM recorded in step 9.
If
another RCO2 PM requires re-
covery
(continued)
Do
step 18
step 28
Do
step 25
step 25
step 29
step 35
;MsgCond:OPN,Restricted
Do
step 32
step 32
step 17
Do
step 11