Replacing an NTMX74 in an RSC-M
At your current location
1
Proceed if you have been directed to this card replacement procedure:
Obtain an NTMX74 replacement card. Verify that the replacement card has
the same product engineering code (PEC), and PEC suffix, as the card to
remove.
At the MAP terminal
2
Set the MAP display to the peripheral module (PM) level. To post the
RSC-M/RCO2, type:
>MAPCI;MTC;PM;POST RCO2 rco2_no
and press the Enter key.
where
Example of a MAP display:
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
WARNING
Loss of service
When you replace a card in the RSC-M, make sure
that the unit in which you replace the card is
inactive. Make sure that the mate unit is active.
from a step in a maintenance procedure
to use the procedure to verify or accept cards
by your maintenance support group.
rco2_no
is the number of the RCO2 with the defective card
RSC-M card replacement procedures
in an RSC-M
6-43