Nortel DMS 100 Series Maintenance Manual page 261

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

devices (or units). You must power down both units before removal of the
associated NTRX42 circuit card.
At the MAP terminal
5
Set the MAP display to the peripheral module (PM) level. To post the
RSC-M/RCO2 that the NTRX42 circuit breaker card powers, type
>MAPCI;MTC;PM;POST RCO2 rco2_no
and press the Enter key.
where
Example of a MAP response:
RCO2
0 Quit
2 Post_
3 ListSet
4
5 TRNSL
6 TST
7 BSY
8 RTS
9 OffL
10 LoadPM_
11 Disp_
12 Next_
6
To determine the location of the RSC-M units or extension (EXT) half shelves
that the circuit card you replace powers, type
>QUERYPM
and press the Enter key.
Example of a MAP response:
PM Type: RCO2 PM No.: 0 PM Int. No.: 9 Node_No: 24
PMs Equipped: 53 Loadname:KRI07BI1 EEPRom Load:MX77NG03
WARM SWACT is supported and available
RCO2 0 is included in the REX schedule.
REX on RCO2 0 has not been performed.
Node Status: {OK, FALSE}
Unit 0 Act,
Unit 1 Inact, Status: {OK, FALSE}
Site Flr RPos Bay_id Shf Description Slot EqPEC
HOST 00
HOST 00
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
rco2_no
is the number of the RCO2 that the NTRX42 card powers
SysB
PM
0
RCO2
0
RCO2
0 ISTb
Unit0:
Inact ISTb
Unit1:
Act InSv
Status: {OK, FALSE}
C02
LTEI 00
C02
CEXT 00
RSC-M card replacement procedures
in an RSC-M/MSP
ManB
OffL
CBsy
0
2
0
0
0
Links_OOS:
CSide
1, PSide
05
RCO2 000
47
EXT:LEFT
01:13 MX86AA
6-109
NTRX42
(continued)
ISTb
InSv
2
25
0
1
1
1
MX85AA