Ntmx76 In An Rsc-M - Nortel DMS 100 Series Maintenance Manual

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

Application
Use this procedure to replace an NTMX76 circuit card in a Remote Switching
Center Multi-access (RSC-M) main shelf.
Note: In this section, RSC-M is referred to as RCO2 in the examples.
When software outputs messages to the MAP terminal, the software does
not differentiate between the two types of RCO2.
PEC
NTMX76
Common procedures
Two common procedures are referenced in this section:
Action
This procedure contains a summary flowchart and a list of steps. Use the
flowchart to review the procedure. Follow the steps to perform the procedure.
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
Suffixes
AA, AB
replacing a card
returning a card
RSC-M card replacement procedures 6-57
Name
Message and tones card
NTMX76
in an RSC-M