Nortel DMS 100 Series Maintenance Manual page 339

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

Recovering an out-of-service RSC-M/RCO2
RESET
STATUS
RUN
INITIALIZE
LOADING DATA
If the unit
did not initialize
initialized
23
Determine if the NO REPLY FROM PM message appears.
If the message
appears
does not appear
24
Determine if the NO WAI AFTER RESET message appears.
If the message
appears
does not appear
25
Check the card list at the MAP terminal.
Example of a MAP response:
SITE FLR RPOS
RSCM
RSCM
If all of the cards
are replaced
are not replaced
26
Go to the Card Replacement Procedures section in this document for the next
card on the list. Complete the card replacement procedures and go to step
17.
27
To load the unit, type
>LOADPM UNIT unit_no CC
and press the Enter key.
where
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
BAY_ID SHF DESCRIPTION SLOT EQPEC
00
M07
LTEI 00
00
M07
LTEI 00
RSC-M recovery procedures
Do
step 23
step 27
Do
step 35
step 24
Do
step 25
step 18
05
RCO2 : 001
03
05
RCO2 : 001
25
Do
step 35
step 26
11-13
(continued)
MX77
MX77

Advertisement

Table of Contents
loading

Table of Contents