Nortel DMS 100 Series Maintenance Manual page 139

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

If TST
fails
15
16
To return the link to service, type
>RTS LINK link_no
and press the Enter key.
fails
17
To post the RCO2, type
>POST RCO2 rco2_no
where
Note: This RCO2 must be ISTB.
18
To return the inactive unit to service, type
>RTS UNIT unit_no
If RTS
passes
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
is the PLGC posted in step 8
host_pm_no
is the number of the link identified in step 9
rco2_no
is the number of the RCO2 identified in step 2
is the number of the RCO2 posted in step 19
RSC-M alarm clearing procedures
PM RSC-M/RCO2
Major
Do
step 29
Do
step 19
step 29
Do
step 19
5-29
(continued)