Nortel DMS 100 Series Maintenance Manual page 173

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

To replace an NT6X92 in an RSC-M
At the MAP display
1
Proceed if one of the following conditions apply:
2
Obtain an NT6X92 replacement circuit card. Make sure the replacement
circuit card has the same product engineering code (PEC) and PEC suffix, as
the circuit card to be removed.
At the MAP terminal
3
To access the peripheral module (PM) level of the MAP display and to post
the RSC-M/RCO2 with the defective card, type:
>MAPCI;MTC;PM;POST RCO2 rco2_no
and press the Enter key.
where
Example of a MAP response:
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
a step in a maintenance procedure directed you to this card replacement
procedure
you use this procedure to verify or accept cards
the maintenance support group directed you to this procedure
WARNING
Loss of service
When you replace a card in the RSC-M, make sure the unit in
which you replace the card is inactive and the mate unit is
active.
rco2_no
is the PM number zero to 255
RSC-M card replacement procedures
in an RSC-M
6-21
NT6X92