Nortel DMS 100 Series Maintenance Manual page 234

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

6-82 RSC-M card replacement procedures
NTMX82
in an RSC-M
(continued)
RCO2 P-side link connections (Sheet 2 of 2)
Card Location
RCO2 main shelf,
position 19 (optional)
Right extension half shelf
Provisioned RCO2 shelf,
position 33
7
297-8223-550 Standard 04.02 November 2000
Links for
MX87
MX82
Slot No.
Card 0
6
32, 33
8
40, 41
12
0, 1
16
8, 9
14
16, 17
19
40, 41
21
32, 33
23
24, 25
12
0, 1
16
8, 9
14
16, 17
Note: Proceed to step 10.
To post the host PM, type
>POST host_pm host_pm_no
and press the Enter key.
where
host_pm
is a PCM-30 line group controller (PLGC)
host_pm_no
is the number of the PLGC that connects to the defective card
Example of a MAP display:
Links for
Links for
MX82
MX82
Card 1
Card 2
34, 35
36, 37
42, 43
44, 45
2, 3
4, 5
10, 11
12, 13
18, 19
20, 21
42, 43
44, 45
34, 35
36, 37
26, 27
28, 29
2, 3
4, 5
10, 11
12, 13
18, 19
20, 21
Links for
MX82
Card 3
38, 39
46, 47
6, 7
14, 15
22, 23
46, 47
38, 39
30, 31
6, 7
14, 15
22, 23

Advertisement

Table of Contents
loading

Table of Contents