Nortel DMS 100 Series Maintenance Manual page 233

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

6
RCO2 P-side link connections (Sheet 1 of 2)
Card Location
RCO2 main, shelf,
pos. 05
Left extension half shelf
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
If C-side links
are not defective
To display the peripheral-side (P-side) links that associate with the NTMX82
circuit card, type
>TRNSL P
and press the Enter key.
Example of a MAP response
Link
0:
REM1 11 0
Link
1: Carrier of Class – Trunk ;Status:OK
Link
2: Carrier of Class – Trunk ;Status:SBsy
Link
3: Carrier of Class – Trunk ;Status:SBsy
Link
4: Carrier of Class – Trunk ;Status:SBsy
Link
5: Carrier of Class – Trunk ;Status:OK
Link
6: Carrier of Class – Trunk ;Status:OK
Link
7: Carrier of Class – Trunk ;Status:OK
Link
8:
REM1 11 1 0;Cap MS;Status:OK;
The following table displays the P-side link configuration for an RSC-M
cabinet. The cabinet has three RCO2 main shelves and two extension half
shelves.
Note 1: Other configurations, like two RCO2 main shelves and four
extension half shelves, can be provisioned in an RCO2 cabinet. For P-side
link configurations other than the link that the following table describes,
consult office administration, or review office records.
Note 2: The RCO2 can have an associated extension half shelf. Consult
office administration, or review office records for the P-side link
configuration for the extension half shelf.
Note 3: The NTMX82 packlets bear the numbers 0 through 3 from the top
of each NTMX87 circuit card.
Links for
MX87
MX82
Slot No.
Card 0
12
0, 1
16
8, 9
14
16, 17
4
24, 25
RSC-M card replacement procedures
in an RSC-M
Do
step 6
0;Cap MS;Status:OK
Links for
Links for
MX82
MX82
Card 1
Card 2
2, 3
4, 5
10, 11
12, 13
18, 19
20, 21
26, 27
28, 29
6-81
NTMX82
(continued)
;MsgCond:OPN
MsgCond:OPN
Links for
MX82
Card 3
6, 7
14, 15
22, 23
30, 31

Advertisement

Table of Contents
loading

Table of Contents