Ntmx74 In An Rsc-M - Nortel DMS 100 Series Maintenance Manual

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

Application
Use this procedure to replace an NTMX74 card in the Remote Switching
Center Multi-Access (RSC-M) shelf.
Note: In this section RSC-M is referred to as RCO2 in the examples. When
software outputs messages to the MAP terminal the system does not
differentiate between the two types of RCO2.
PEC
NTMX74
Common procedures
None
Action
This procedure contains a summary flowchart and a list of steps. Use the
flowchart to review the procedure. Follow the steps to perform the procedure.
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
Suffixes
Name
AB
DS30A Interface
RSC-M card replacement procedures 6-41
NTMX74
in an RSC-M