Nortel DMS 100 Series Maintenance Manual page 236

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

6-84 RSC-M card replacement procedures
NTMX82
in an RSC-M
(continued)
RCO2 C-side link connections
10
11
297-8223-550 Standard 04.02 November 2000
C-side
Slot 9
0
0
1
4
1
5
8
2
9
12
3
13
NTMX82 packlet slot number in the NTMX87
card in the specified card slots
Record the RCO2 number, shelf location, slot number, and numbers of the
associated links for the circuit card you want to replace.
To manually busy (ManB) the links that connect to the defective circuit card,
type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of the link that associate with the defective NTMX82
circuit card
Note 1: Each NTMX82 circuit card has two associated links. Each link
must be ManB. Possible link number pairs are as follows: 0 & 1; 2 & 3; 4
& 5; or 6 & 7.
Note 2: To busy the other links that associate with the RCO2, execute this
step for each link until all links are busy.
Slot 19
2
3
6
7
10
11
14
15
0
NTMX82
1
packlets
2
3
NTMX87 card