Replacing an NTMX76 in an RSC-M
At the MAP display
1
Proceed if:
2
Obtain an NTMX76 replacement circuit card. Make sure the replacement
circuit card has the same product engineering code (PEC), and PEC suffix,
as the circuit card you remove.
At the MAP terminal
3
Make sure the peripheral module (PM) level appears on the MAP display. To
post the RSC-M/RCO2, type:
>MAPCI;MTC;PM;POST RCO2 rco2_no
and press the Enter key.
where
Example of a MAP response:
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
a step in a maintenance procedure directs you to this card replacement
procedure
you use the procedure to verify or accept cards
your maintenance support group directs you to this procedure.
WARNING
Loss of service
When you replace a card in the RSC-M, make sure the unit in
which you replace the card is inactive. Make sure that the
mate unit is active.
rco2_no
is the number of the RCO2 with the defective card(s)
RSC-M card replacement procedures
in an RSC-M
6-59
NTMX76
(continued)