Nortel DMS 100 Series Maintenance Manual page 123

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

4
To check for fault indicators, type
>querypm
and press the Enter key.
Example of a MAP display:
CM
.
RCO2
0 Quit
2 Post_
3 ListSet
4
5 TRNSL_
6 Tst_
7 Bsy_
8 RTS_
9 OffL
10 LoadPM_
11 Disp_
12 Next
13 SWACT
14 QueryPM
15
16
17 Perform
18
5
Use the following information to determine the next step.
If the RCO2
is SysB
is CBsy
6
Check for PM180 and PM181 logs. These logs indicate that the RCO2 is in
emergency stand-alone (ESA). Perform this check according to local
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
flT
MS
IOD
Net
PM
.
.
.
1RCO2
*C*
SysB
ManB
PM
1
RCO2
1
RCO2
0 CBsy
Links_OOS:
Unit0:
Act
CBsy
Unit1:
Inact CBsy
QUERYPM FLT
Unit0
Static data not updated
Unit1
Reset
DANGER
The RCO2 can be in ESA
A CBsy indicator can change to a SysB indicator if the RCO2
is in emergency stand-alone (ESA) mode. The system
generates PM180 and PM181 logs to indicate ESA. The
system only supports local calls.
RSC-M alarm clearing procedures
PM RSC-M/RCO2
critical
CCS
Lns
Trks
.
.
OffL
CBsy
0
1
2
0
2
2
CSide
1, PSide
Do
step 6
step 15
5-13
(continued)
Ext
APPL
.
.
.
ISTb
InSv
4
12
2
9
0