Replacing an NTMX82 in an RSC-M
At the MAP display
1
Proceed to step 2 if one of the following conditions applies:
2
Obtain an NTMX82 replacement circuit card. Make sure the replacement
circuit card has the same product equipment code (PEC) and PEC suffix as
the circuit card to remove.
At the MAP terminal
3
To post the RSC-M/RCO2 with the defective card(s), type
>MAPCI;MTC;PM;POST RCO2 rco2_no
and press the Enter key.
where
Example of a MAP response:
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
another maintenance procedure directed you to this card replacement
procedure
you use the procedure to verify or accept cards
your maintenance support group directed you to this procedure
WARNING
Loss of service
When you replace an NTMX82 circuit card in RSC-M, both
links that the circuit card serves must be BSY. Active calls
on the affected links are lost. Execute this procedure in
periods of low traffic.
rco2_no
is the number of the RCO2 with the defective card(s)
RSC-M card replacement procedures
in an RSC-M
6-79
NTMX82
(continued)