Where Unit_No - Nortel DMS 100 Series Maintenance Manual

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

12
Use the following information to determine the next step:
If you
are directed to this procedure from a maintenance
procedure
are not directed to this procedure from a maintenance
procedure
13
Remove the sign from the active unit. Return to the maintenance procedure
that sent you to this procedure and continue as directed.
14
To load the CLASS modem resource (CMR) in the inactive RCO2 unit, type:
>LOADPM
and press the Enter key.
where
If LOAD
passes
fails
15
To return to service (RTS) the CMR in the inactive RCO2 unit, type:
>RTS UNIT unit_no
and press the Enter key.
where
If RTS
passes
fails
At the cabinet
16
Remove the sign from the active RCO2 unit.
17
Go to the common returning a card procedure in this document.
18
This procedure is complete. Return to the maintenance procedure that
directed you to this card replacement procedure and continue as directed.
19
For additional help, contact the next level of support.
DMS-100 Family Remote Switching Center Multi-Access Maintenance Manual XPM11 and up
UNIT unit_no CC CMR
unit_no
is the number of the inactive RCO2 unit
CMR
unit_no
is the number of the RCO2 unit loaded in step 15
RSC-M card replacement procedures
in an RSC-M
Do
step 15
step 19
Do
step 16
step 19
6-17
NT6X78
(continued)
Do
step 13
step 14

Advertisement

Table of Contents
loading