Nortel DMS 100 Series Maintenance Manual page 196

Remote switching center multi-access
Hide thumbs Also See for DMS 100 Series:
Table of Contents

Advertisement

6-44 RSC-M card replacement procedures
NTMX74
in an RSC-M
(continued)
3
4
5
At the RSC-M cabinet
6
297-8223-550 Standard 04.02 November 2000
CM
MS
IOD
.
.
.
RCO2
SysB
0 Quit
PM
0
2 Post_
RCO2
0
3 ListSet
4
RCO2
0 ISTb
5 TRNSL
Unit0:
Inact InSv
6 TST
Unit1:
Act InSv
7 BSY
8 RTS
9 OffL
10 LoadPM_
11 Disp_
12 Next_
13 SWACT
14 QueryPM
15
16
17 Perform
18
Observe the MAP display. Make sure that the card you remove is on the
inactive unit.
If defective card is on
active unit
inactive unit
To perform a Switch of Activity (SWACT) of the processing activity, to the
inactive unit, type:
>SWACT
and press the Enter key.
To confirm the system prompt, type:
>YES
and press the Enter key.
After the two units are in-service, proceed to the next step.
Place a sign on the active unit that bears the words Active unit-Do not touch .
Do not use magnets or tape to attach this sign.
Net
PM
CCS
.
1RCO2
.
ManB
OffL
0
2
0
0
Links_OOS:
CSide
Do
step 4
step 6
LNS
Trks
Ext
.
.
.
CBsy
ISTb
0
2
0
1
1, PSide
1
Appl
.
InSv
25
1